[1]赵赫,张宏伟,王亮,等.臭氧预氧化对混凝-超滤处理微污染水的影响[J].天津大学学报(自然科学版),2018,(02):215-220.[doi:10.11784/tdxbz201702002]
 Zhao He,Zhang Hongwei,Wang Liang,et al.Effect of Pre-Ozonation on the Performance of Coagulation-Ultrafiltration Combined Process for Micro-Polluted Water Treatment[J].Journal of Tianjin University,2018,(02):215-220.[doi:10.11784/tdxbz201702002]
点击复制

臭氧预氧化对混凝-超滤处理微污染水的影响

参考文献/References:

[1] Gao W, Liang H, Ma J, et al. Membrane fouling control in ultrafiltration technology for drinking water production:A review[J]. Desalination, 2011, 272(1):1-8.
[2] Singer P C. Humic substances as precursors for potentially harmful disinfection by-products[J]. Water Science and Technology, 1999, 40(9):25-30.
[3] Chang E E, Chiang P C, Ko Y W, et al. Characteristics of organic precursors and their relationship with disinfection by-products[J]. Chemosphere, 2001, 44(5):1231-1236.
[4] Uyak V, Koyuncu I, Oktem I, et al. Removal of trihalomethanes from drinking water by nanofiltration membranes[J]. Journal of Hazardous Materials, 2008, 152(2):789-794.
[5] Jermann D, Pronk W, Meylan S, et al. Interplay of different NOM fouling mechanisms during ultrafiltration for drinking water production[J]. Water Research, 2007, 41(8):1713-1722.
[6] 管运涛, 曹鹏飞, 张锡辉. 净化南方水库源水的混凝-超滤组合工艺[J]. 清华大学学报:自然科学版, 2010, 50(9):1416-1420.
Guan Yuntao, Cao Pengfei, Zhang Xihui. Integrated coagulation and ultrafiltration for purification of reservoir water in southern China[J]. Journal of Tsinghua University:Science and Technology, 2010, 50(9):1416-1420(in Chinese).
[7] Petrusevski B, van Breemen A N, Alaerts G. Effect of permanganate pre-treatment and coagulation with dual coagulants on algae removal in direct filtration[J]. Aqua, 1996, 45(6):316-326.
[8] Plummer J D, Edzwald J K. Effect of ozone on algae as precursors for trihalomethane and haloacetic acid production[J]. Environmental Science & Technology, 2001, 35(18):3661-3668.
[9] Plummer J D, Edzwald J K. Effects of chlorine and ozone on algal cell properties and removal of algae by coagulation[J]. Journal of Water Supply:Research and Technology-AQUA, 2002, 51(6):307-318.
[10] Song Y, Deng Y, Jung C. Mitigation and degradation of natural organic matters(NOMs)during ferrate(Ⅵ) application for drinking water treatment[J]. Chemosphere, 2016, 146:145-153.
[11] Lin T, Pan S, Chen W, et al. Role of pre-oxidation, using potassium permanganate, for mitigating membrane fouling by natural organic matter in an ultrafiltration system[J]. Chemical Engineering Journal, 2013, 223:487-496.
[12] Schlichter B, Mavrov V, Chmiel H. Study of a hybrid process combining ozonation and microfiltration/ultrafil-tration for drinking water production from surface water[J]. Desalination, 2004, 168:307-317.
[13] Song Y, Dong B, Gao N, et al. Huangpu River water treatment by microfiltration with ozone pretreatment[J]. Desalination, 2010, 250(1):71-75.
[14] Camel V, Bermond A. The use of ozone and associated oxidation processes in drinking water treatment[J]. Water Research, 1998, 32(11):3208-3222.
[15] 王东升. 微污染原水强化混凝技术[M]. 北京:科学出版社, 2009.
Wang Dongsheng. Enhanced Coagulation Technology for Micro Polluted Raw Water[M]. Beijing:Science Press, 2009(in Chinese).
[16] 郭召海, 杨敏, 张昱, 等. 预臭氧与后臭氧-生物活性炭联用工艺研究[J]. 环境科学, 2005, 26(6):79-83.
Guo Zhaohai, Yang Min, Zhang Yu, et al. Study on the combination of preozonation and post-ozonation-BAC process for drinking water treatment[J]. Environment Science, 2005, 26(6):79-83(in Chinese).
[17] Edzwald J K. Coagulation in drinking water treatment:Particles, organics and coagulants[J]. Water Science and Technology, 1993, 27(11):21-35.
[18] 魏群山, 罗专溪, 陈强, 等. 天然水体溶解性有机物(DOM)分级组分对典型城市源污染的荧光响应[J]. 环境科学研究, 2010, 23(10):1229-1235.
Wei Qunshan, Luo Zhuanxi, Chen Qiang, et al. Florescence responses of dissolved organic matter (DOM) fractions to typical urban source pollution in natural water[J]. Research of Environmental Sciences, 2010, 23(10):1229-1235(in Chinese).
[19] Coble P G. Characterization of marine and terrestrial DOM in seawater using excitation-emission matrix spectroscopy[J]. Marine Chemistry, 1996, 51(4):325-346.
[20] Sazawa K, Tachi M, Wakimoto T, et al. The evaluation for alterations of DOM components from upstream to downstream flow of rivers in Toyama(Japan)using three-dimensional excitation-emission matrix fluorescence spectroscopy[J]. International Journal of Environmental Research and Public Health, 2011, 8(5):1655-1670.
[21] Owen D M, Amy G L, Chowdhury Z K, et al. NOM characterization and treatability[J]. Journal-American Water Works Association, 1995, 87(1):46-63.
[22] 陈卫, 袁哲, 陶辉, 等. SUVA 值与超滤膜污染的关系[J]. 华中科技大学学报:自然科学版, 2011, 39(2):129-132.
Chen Wei, Yuan Zhe, Tao Hui, et al. Relationship between SUVA value and ultrafiltration pollution[J]. Journal of Huazhong University of Science and Technology:Natural Science Edition, 2011, 39(2):129-132 (in Chinese).
[23] 刘海龙, 王东升, 王敏, 等. 臭氧对有机物混凝的影响[J]. 环境科学, 2006, 27(3):454-460.
Liu Hailong, Wang Dongsheng, Wang Min, et al. Effects of pre-ozonation on organic matter coagulation[J]. Environment Science, 2006, 27(3):454-460(in Chinese).
[24] 董秉直, 曹达文, 陈艳. 饮用水膜深度处理技术[M]. 北京:化学工业出版社, 2006.
Dong Bingzhi, Cao Dawen, Chen Yan. Advanced Treatment Technology of Drinking Water Membrane[M]. Beijing:Chemical Industry Press, 2006(in Chinese).

相似文献/References:

[1]谭欣,何振雄,霍爱群.非整比纳米TiO(2-X)膜光催化降解水中微量卤代烃[J].天津大学学报(自然科学版),2000,(03):360.
[2]李新禹,刘俊杰,裴晶晶,等.常温下臭氧半衰期实验及理论分析[J].天津大学学报(自然科学版),2007,(08):952.
[3]刘俊杰,李艳菊,裴晶晶.室内臭氧与甲苯相互反应产生超细颗粒物的研究[J].天津大学学报(自然科学版),2008,(10):1258.
[4]张凤宝,张国亮,王绍亭.血液透析超滤一维传质动力学模型的摄动解[J].天津大学学报(自然科学版),1997,(02):129.

备注/Memo

收稿日期: 2017-02-05; 修回日期: 2017-04-05.
作者简介: 赵赫(1977—), 女, 博士研究生, zhh2002214030@163.com.
通讯作者: 张宏伟, hwzhang@tju.edu.cn.
网络出版时间: 2017-04-26.网络出版地址: http://kns.cnki.net/kcms/detail/12.1127.N.20170426.1504.004.html.
基金项目: 国家自然科学基金资助项目(51638011, 51478314); 国家重点研发计划资助项目(2016YFC0400503); 天津市科技计划资助项目(14ZCDGSF00128); 河北省建设科技研究指导性计划资助项目(2014-236).
Supported by National Natural Science Foundation of China(No.,51638011 and No.,51478314), the National Key Research and Development Program of China(No.,2016YFC0400503), the Science and Technology Project of Tianjin(No.,14ZCDGSF00128), and the Hebei Province Guideline Plans for Construction Science and Technology Research Projects(No.,2014-236).

更新日期/Last Update: 2018-02-10