|本期目录/Table of Contents|

[1]郭 猛,姚谦峰.密肋复合墙体刚度退化全过程分析[J].天津大学学报(自然科学版),2010,(09):792-797.
 GUO Meng,YAO Qian-feng.Stiffness Degradation Process Analysis of Multi-Ribbed Composite Wall[J].Journal of Tianjin University,2010,(09):792-797.
点击复制

密肋复合墙体刚度退化全过程分析()
分享到:

《天津大学学报(自然科学版)》[ISSN:0493-2137/CN:12-1127/N]

卷:
期数:
2010年09
页码:
792-797
栏目:
建筑工程
出版日期:
2010-09-15

文章信息/Info

Title:
Stiffness Degradation Process Analysis of Multi-Ribbed Composite Wall
作者:
郭 猛姚谦峰
北京交通大学土木建筑工程学院,北京 100044
Author(s):
GUO MengYAO Qian-feng
School of Civil Engineering,Beijing Jiaotong University,Beijing 100044,China
关键词:
密肋复合墙体低周反复荷载试验特征点刚度刚度退化影响因素
Keywords:
multi-ribbed composite walllow-cyclic reversed loading testcharacteristic point stiffnessstiffness degradationinfluencing factor
分类号:
TU315
文献标志码:
A
摘要:
密肋复合墙是密肋壁板结构体系的主要抗侧力构件,复合墙在荷载作用下的刚度退化规律是研究密肋结构体系抗震性能的基础性问题之一.由1/2比例密肋复合墙体低周反复荷载试验,得出了复合墙各个特征点刚度和从加荷到破坏全过程的三阶段刚度退化规律,分析了轴压比等因素对复合墙刚度退化的影响,即轴压比越大,剪跨比、外框架截面及配筋、肋柱(梁)数量及配筋越小,刚度退化速度越快,反之则越慢;同时给出了复合墙刚度退化曲线指数表达式和各变形阶段的退化系数表.讨论了改善施工工艺、采用纤维填充材料等延缓复合墙刚度退化速度的方法,为密肋壁板结构体系的工程应用提供了参考.
Abstract:
Multi-ribbed composite wall is the main anti-lateral force component in multi-ribbed slab structure systemand the law of its stiffness degradation under load is one of the fundamental problems about seismic performance of multi-ribbed slab structures. Low-cyclic reversed loading tests were conducted on composite wall samples with theratio of 1∶2,in which the characteristic point stiffness and the law of their stiffness degradation process from load-ing to failure were studied,and the effect of main influencing factors such as axial compression ratio on the wall stiff-ness degeneration was analyzed. The results show that with the increase of axial compression ratio,the decrease of theshear span ratio,outside frame section and its reinforcement ratio,rib column(beam)quantity,the speed of stiff-ness degradation increased. Otherwise it decreased. The stiffness degradation formula and degradation coefficients indifferent deformation stages were presented and methods to delay stiffness degradation with construction techniqueimprovement and fibers as stuffing materials were also discussed. The study has provided reference for the applicationof multi-ribbed slab structure.

相似文献/References:

[1]姜忻良,苗纪奎,陈志华.方钢管混凝土柱-钢梁隔板贯通节点抗震性能试验[J].天津大学学报(自然科学版),2009,(03):194.
 JIANG Xin-liang,MIAO Ji-kui,CHEN Zhi-hua.Experiment on Seismic Performance of Diaphragm-Through Joint Between Concrete-Filled Square Steel Tubular Column and Steel Beam[J].Journal of Tianjin University,2009,(09):194.
[2]李砚波,曹 晟,陈志华,等. 钢管束混凝土组合墙-梁翼缘加强型节点抗震性能试验[J].天津大学学报(自然科学版),2016,(增刊1):41.[doi:10.11784/tdxbz201605008]
 Li Yanbo,Cao Sheng,Chen Zhihua,et al. Experiment on Seismic Performance of Bundled Lipped Channel-Concrete Composite Wall and Beam-Flange-Strengthened Connections[J].Journal of Tianjin University,2016,(09):41.[doi:10.11784/tdxbz201605008]
[3]周晓洁,等. 柔性连接填充墙框架结构抗震性能试验[J].天津大学学报(自然科学版),2015,(02):155.[doi:10.11784/tdxbz201410041]
 Zhou Xiaojie,Li Zhongxian,et al. Experiment on Seismic Behavior of Flexible ConnectionMasonry Infilled Frame Structure[J].Journal of Tianjin University,2015,(09):155.[doi:10.11784/tdxbz201410041]

备注/Memo

备注/Memo:
通讯作者:郭 猛,guomeng673@163.com.